ProTec 100
Hos AVS kan du både leje og købe dit trafikværn.
Vil du vide mere, er du velkommen til at kontakte os.
Technical data ProTec 100
Impact test
| Acceptance test: | TB 21 + TB 41 |
| Test date: | 03.05.2011 |
| Containment level: | T1/T 3 |
| Test location: | TÜV Süd, Munich |
| Minimum installation length: | 137 m |
| Ground anchoring: | no |
System description
| Material: | steel and concrete |
| Height: | 0,56 m |
| Element length: | 6,00 m |
| Structural width: | 0,25 m |
| Planning width: | 0,12 m |
| Weight per m: | 124 kg |
Test conditions
| Test vehicle: | car 1,3 t; impact angle 8°; 80 km/h |
| truck 10 t; impact angle 8°; 70 km/h |
Test results
| T3: dyn. deflection 0,55 m + structural width 0,25 m = 0,8 m (corresponds to effective range W2) |
| ASI value: 0,2 (A) |
| T1: dyn. deflection 0,25 m + structural width 0,25 m = 0,5 m (corresponds to effective range W1) |
| ASI value: 0,2 (A) |
Test reports
| Test reports ProTec 100: BASt 2011 7E 56 |
| Test reports reflektor element: BASt V4-64/2010 |